| Steel Test | |||||||
|---|---|---|---|---|---|---|---|
| The following results include barriers being fixed to 1mm 18g steel | |||||||
| Transmission Loss dB|Frequency (Hz) | 65 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
| 12mm Class O foam, 5kg/m2 lead, 6mm Class O foam | 24 | 23 | 25 | 29 | 33 | 46 | 53 |
| 12mm Class O foam, 5kg/m2 PVC, 6mm Class O foam | 23 | 19 | 21 | 35 | 44 | 47 | 54 |
| Vibration | |||||||
|---|---|---|---|---|---|---|---|
| Duct (D) | Panel (P) | |||||||
| Vibration Level Frequency | 65 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
| (D) 900x600 (25mm foam) | - | 5.6 | 6.4 | 10.0 | 18.8 | 15.5 | 7.1 |
| (P) Max 1.800 x900 - Min 1.210 x 600 (12mm) | - | 7.1 | 9.8 | 14.9 | 13.1 | 10.7 | 3.1 |
| (P) Max 1.800 x900 - Min 1.210 x 600 (25mm) | - | 12.3 | 12.0 | 15.4 | 21.4 | 17.5 | 11.3 |
| (P) Max 1.800 x900 - Min 1.210 x 600 (50mm) | - | 15.5 | 12.9 | 21.0 | 25.4 | 19.6 | 12.4 |